NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9:00am - 5:30pm GMT/BST Monday to Friday

Rayleigh Instruments - Multifunction Meters

Multifunction Energy Meters for single phase and three phase MID and non MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus and Mbus. DIN rail mounting, panel mounting models available.

Items 1 to 15 of 28 total

Page:
  1. 1
  2. 2

Grid  List 

  • IME Nemo D4-Le (Rogowski Kit) DIN Rail Mounted Three Phase Network Multifunction...

    • Network monitor + 3 Rogowsk current sensors
    • Three-phase network 80...500V (phase-phase)
    • Connection on dedicated Rogowski current sensors
    • Pulse output and RS485 communication by ModBus RTU/TCP or BACNET protocol
    Call for Prices

  • IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multifunction Met...

    • 4 module DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Isolated input
    • Phase sequence diagnostics
    • Pulsed output, Modbus RS485 communication or M-Bus communication
    • –/1A, –/5A current transformer operated
    • 50…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    Call for Prices

  • IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
    Call for Prices

  • IME Nemo D4-DC Multifunction Network Monitor for Direct Current (DC)

    • Voltage input 10...300Vdc
    • Direct voltage input by external adapter up to 1500V
    • Direct current input or from shunt (selectable)
    • Direct input up to 10A direct current
    • Input from shunt 60 – 100 – 150mV
    • 2 programmable alarms
    • Integrated Communication Protocols are Pulsed output and RS485 Modbus RTU
    Call for Prices

  • IME Nemo 72-L Panel Mounted Multifunction Meter Single and Three Phase Network w...

    • 72 x 72mm panel mounting meter
    • Single-phase network 50...290V
    • Three-phase network 80...500V (phase - phase)
    • Current Transformer Input :- Current rating In: 5a or 1a
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor, Partial active energy (resettable), Hours run, Phase sequence diagnostics
    • Integrated Communication Protocols are *Pulsed output or *RS485 Modbus RTU (*depending on model ordered)
    • True RMS value measurement
    • External CT and VT programmable (External CT ratio: 1...9999) - (External VT ratio: 1...10,0)
    • Programmable voltage transformer ratio
    • Auxillary Supply - Rated value Uaux ac: 48 - 115 – 230 e 240v
    Call for Prices

  • IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Pulse and RS485 output
    Call for Prices

  • IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...

    • Kilowatt hour meter / active energy meter
    • 72 x 72mm flush panel mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Power demand
    • Power max demand (resettable)
    • Partial active and reactive energy (resettable)
    • Phase Current
    • Phase to phase and phase to neutral voltage
    • Frequency
    • Phase active power
    • Phase reactive power
    • 3 phase active/reactive and apparent power
    • Power factor
    • –/1A or –/5A current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulsed output
    • Programmable CT ratios
    Call for Prices

  • IME Conto D2 Class 1 Single Phase Network kWh Energy Meter (Not MID Certificated...

    • Kilowatt hour / active energy meter
    • 2 module wide
    • DIN rail mounted
    • Single phase network
    • Input current 10(63)A
    • Input voltage 230V
    • Active energy class B (EN50470)
    • Reactive energy class 2 (EN60253-23)
    • Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
    • LCD Display 5+1= 999999.9
    • Self supplied auxiliary
    • Pulse or RS485 Modbus RTU (depending on model)
    Call for Prices

Items 1 to 15 of 28 total

Page:
  1. 1
  2. 2

Grid  List