NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9:00am - 5:30pm GMT/BST Monday to Friday

Rayleigh Instruments - Multifunction Meters

Multifunction Energy Meters for single phase and three phase MID and non MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus and Mbus. DIN rail mounting, panel mounting models available.

Items 16 to 30 of 52 total

Page:
  1. 1
  2. 2
  3. 3
  4. 4

Grid  List 

  • Rayleigh Instruments RI-D240 Multifunction Energy Meters

    • Energy pulse LED
    • -/1A or -/5A CT input
    • Single phase or three phase network compatible
    • Programmable voltage and CT ratio
    • True RMS measurement
    • Cost effective and accurate
    • Modbus or Mbus communication
    Call for Prices

  • Rayleigh Instruments RI-D35-100 Single Phase Multifunction Energy Meter - MID Ce...

    • 100A direct connected
    • High definition LCD display
    • Import and export energy measurement
    • Modbus or Mbus Versions
    • Two pulse outputs
    • MID B+D Certified
    • LED pulse indication
    Call for Prices

  • IME Nemo 96HDL - easywire®

    • Built in single pulse output with 1 slot for plug in communications modules
    • DIN 96x96mm, flush mounting, Backlit LCD display
    • Single phase or 3-phase 4-wire unbalanced load operation
    • Auxiliary voltage self supplied
    • RJ45 connected 330mV Input selectable CTs
    • Programmable VT ratio 100V...500KV
    • Selectable CT phase correction allows reversal of L1 and L3
    • - Direct voltage input 140 to 460V (phase to phase)
    • - Voltage input via VT upto 1200V on VT primary
    • Measured Quantities: Voltage, Current, Energy, Power, Frequency, Power Factor
    Call for Prices

  • Rayleigh Instruments RI-F421 (80-500V) Single and Three Phase Network High Accur...

    • DIN 96x96mm flush mounting meter with backlit LCD display
    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-500V 50/60 Hz (phase to phase)
    • Current Transformer Connected 1A or - 5A CT Input
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Programmable settings:
    • Input current via CT 5/5A to 50000/5A or 5/1A to 50000/1A
    • Direct voltage input 80 to 500V (phase to phase)
    • Voltage input via VT upto 1000V on VT primary
    Call for Prices

  • IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multifunction Met...

    • 4 module DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Isolated input
    • Phase sequence diagnostics
    • Pulsed output, Modbus RS485 communication or M-Bus communication
    • –/1A, –/5A current transformer operated
    • 50…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    Call for Prices

  • IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
    Call for Prices

  • IME Nemo D4-DC Multifunction Network Monitor for Direct Current (DC)

    • Voltage input 10...300Vdc
    • Direct voltage input by external adapter up to 1500V
    • Direct current input or from shunt (selectable)
    • Direct input up to 10A direct current
    • Input from shunt 60 – 100 – 150mV
    • 2 programmable alarms
    • Integrated Communication Protocols are Pulsed output and RS485 Modbus RTU
    Call for Prices

  • IME Nemo 72-L Panel Mounted Multifunction Meter Single and Three Phase Network w...

    • 72 x 72mm panel mounting meter
    • Single-phase network 50...290V
    • Three-phase network 80...500V (phase - phase)
    • Current Transformer Input :- Current rating In: 5a or 1a
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor, Partial active energy (resettable), Hours run, Phase sequence diagnostics
    • Integrated Communication Protocols are *Pulsed output or *RS485 Modbus RTU (*depending on model ordered)
    • True RMS value measurement
    • External CT and VT programmable (External CT ratio: 1...9999) - (External VT ratio: 1...10,0)
    • Programmable voltage transformer ratio
    • Auxillary Supply - Rated value Uaux ac: 48 - 115 – 230 e 240v
    Call for Prices

  • Inepro PRO1-Standard 45A MID Certified Single Tariffs Single Phase Network Mult...

    • Single phase network active energy meter
    • MID Certified (B and D)
    • 45A Direct connected
    • Single Tariff
    • 17.5mm wide/1 Module
    • Din Rail Mounted
    • LCD Display 5+2= 99999.99
    • Measured voltage 230V 50 Hz
    • Calculation of total energy : Forward, Forward+Reverse, Forward-Reverse, Reverse-Forward, Reverse
    • Pulse output (settable S0)
    Call for Prices

  • IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Pulse and RS485 output
    Call for Prices

  • IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...

    • Kilowatt hour meter / active energy meter
    • 72 x 72mm flush panel mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Power demand
    • Power max demand (resettable)
    • Partial active and reactive energy (resettable)
    • Phase Current
    • Phase to phase and phase to neutral voltage
    • Frequency
    • Phase active power
    • Phase reactive power
    • 3 phase active/reactive and apparent power
    • Power factor
    • –/1A or –/5A current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulsed output
    • Programmable CT ratios
    Call for Prices

Items 16 to 30 of 52 total

Page:
  1. 1
  2. 2
  3. 3
  4. 4

Grid  List