NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9:00am - 5:30pm GMT/BST Monday to Friday

IME - Multifunction Meters

IME Italy - Strategic UK Partner

IME Nemo range of Multifunction Energy Meters for single phase and three phase energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus, Mbus, Bacnet, Profibus and ethernet. These Nemo meters are available as DIN rail mounting and panel mounting models.

IME Strategic UK Partner Products are available to our UK Customers.

7 Item(s)

Grid  List 

  • IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multifunction Met...

    • 4 module DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Isolated input
    • Phase sequence diagnostics
    • Pulsed output, Modbus RS485 communication or M-Bus communication
    • –/1A, –/5A current transformer operated
    • 50…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    Call for Prices

  • IME Nemo 96 HD Panel Mounted Single & Three Phase Network 0.5 Accuracy Class...

    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-500V 50/60 Hz (phase to phase)
    • Auxiliary Voltage 80-265Vac/110-300Vdc
    • -/1A or -/5A CT Input selectable
    Call for Prices

  • IME Nemo 96 HD+ Panel Mounted Single & Three Phase Network 0.5 Accuracy Clas...

    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-690V 50/60 Hz (phase to phase)
    • Auxiliary Voltage 80-265Vac/110-300Vdc
    • -/1A or -/5A CT Input selectable
    Call for Prices

  • IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
    Call for Prices

7 Item(s)