IME Nemo range of Multifunction Energy Meters for single phase and three phase energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus, Mbus, Bacnet, Profibus and ethernet. These Nemo meters are available as DIN rail mounting and panel mounting models.
IME Strategic UK Partner Products are available to our UK Customers.
-
IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multifunction Met...
- 4 module DIN rail mounting
- Single & three phase (3 or 4 wire) network unbalanced load
- Isolated input
- Phase sequence diagnostics
- Pulsed output, Modbus RS485 communication or M-Bus communication
- –/1A, –/5A current transformer operated
- 50…450V direct or VT operated measured voltage
- Programmable current transformer ratio
- Programmable voltage transformer ratio
-
IME Nemo 96 HD Panel Mounted Single & Three Phase Network 0.5 Accuracy Class...
- Single phase or 3-phase, 3 or 4-wire unbalanced load operation
- Measured Voltage 80-500V 50/60 Hz (phase to phase)
- Auxiliary Voltage 80-265Vac/110-300Vdc
- -/1A or -/5A CT Input selectable
-
IME Nemo 96 HD+ Panel Mounted Single & Three Phase Network 0.5 Accuracy Clas...
- Single phase or 3-phase, 3 or 4-wire unbalanced load operation
- Measured Voltage 80-690V 50/60 Hz (phase to phase)
- Auxiliary Voltage 80-265Vac/110-300Vdc
- -/1A or -/5A CT Input selectable
-
IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...
- 4 module wide 71.22mm
- DIN rail mounting
- Single & three phase (3 or 4 wire) network unbalanced load
- Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
- Active energy class 0.5 (EN61557-12)
- Reactive energy class 1 (EN61557-12)
- Partial active energy and reactive energy(resettable)
- Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
- Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
- –/1A or –/5A (selectable) current transformer operated
- 80…450V direct or VT operated measured voltage
- Programmable current transformer ratio
- Programmable voltage transformer ratio
- Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
-
IME Nemo D4-DC Multifunction Network Monitor for Direct Current (DC)
- Voltage input 10...300Vdc
- Direct voltage input by external adapter up to 1500V
- Direct current input or from shunt (selectable)
- Direct input up to 10A direct current
- Input from shunt 60 – 100 – 150mV
- 2 programmable alarms
- Integrated Communication Protocols are Pulsed output and RS485 Modbus RTU
-
IME Nemo 96 HDLe (Rogowski Kit) Panel Mounted Three Phase Network Multifunction ...
- Network monitor + 3 Rogowski current sensors
- Three-phase network 80...500V (phase-phase)
- Pulse output and RS485 communication
-
IME Nemo D4-Le (Rogowski Kit) DIN Rail Mounted Three Phase Network Multifunction...
- Network monitor + 3 Rogowsk current sensors
- Three-phase network 80...500V (phase-phase)
- Connection on dedicated Rogowski current sensors
- Pulse output and RS485 communication by ModBus RTU/TCP or BACNET protocol