-
Home
>
-
Rayleigh Instruments - Electrical Transducers
Rayleigh Instruments - Electrical Transducers
-
- Measures DC current with proportional DC analogue output, Hall Effect
- Cable aperture Ø35mm
- CT with built in transducer
- Measured current up to 1000A dc
- AC or DC supply voltage
Call for Prices
-
- Measures DC current and delivers proportional DC analogue output, Hall Effect
- 80mm (HT2BA) internal aperture
- Current transformer with built in transducer
- Measured current up to 1000A dc
- AC or DC supply voltage
Call for Prices
-
- Measures DC current with proportional DC analogue output, Hall Effect
- Auxialry output to power up to 3 HT1Bs units
- Cable aperture Ø35mm
- CT with built in transducer
- Measured current up to 1000A dc
- AUX output 15Vdc
- AC or DC supply voltage
Call for Prices
-
- DC current transformer/transducer - to measure DC current and deliver a proportional DC analogue output
- DC Current measurement, Hall Effect
- 35mm (HT1Bs) internal aperture
- Current transformer with built in transducer
- Measured current up to 1000A dc
- AUX input 15Vdc
Call for Prices
-
- Measure DC current and delivers proportional DC analogue output
- 35mm internal aperture
- Primary current field selection
- 4 primary ranges and 9 programmable ranges
- Supply voltage 10…34Vdc
- Input 5A…450Aac
- Output 0…20mA, 4…20mA, or 0…10Vdc
- Accuracy Class 1
Call for Prices
-
- Measure single phase AC current and give proportional DC analogue output
- Direct connection up to 225A
- 35mm internal aperture
- Primary current field selection
- 4 primary ranges and 9 programmable ranges
- Supply voltage 230Vac or 115Vac
- Selectable ranges: 5.. 45 – 15...135 – 25...225 – 50...450A
- Output 0...20mA - 4...20mA - 0...10V dc
- Accuracy Class 1
Call for Prices
-
- Alternating current transducer
- Self supplied auxiliary
- Two module
- Single phase AC
- Accuracy 0.5 (20…120% In)
- Current input 1, 1.2, 5 or 6A
Call for Prices
-
- Choice of supply voltages
- Single phase AC
- Accuracy 0.5 (20…120%.In)
- Current input 1, 1.2, 5 or 6A
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Single phase AC
- True R.M.S measurement
- Accuracy 0.5 (20…120% In)
- Current input 1, 1.2, 5 or 6A
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- True R.M.S measurement
- Accuracy 0.5 (20…120% In)
- AC Voltage input
- DC Current or voltage output
- Self supplied auxiliary
Call for Prices
-
- Alternating voltage transducer
- Single phase AC
- AC Voltage input
- Accuracy 0.5 (20…120%.In)
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Single phase AC
- True R.M.S measurement
- AC Voltage input
- Accuracy 0.5 (20…120%.In)
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Fully programmable transducer
- Single or 3-phase, balanced or unbalanced load or via voltage transformer
- Current input via current transformer -/1A or -/5A
- True R.M.S. measurements
- 80…500Vac phase/phase
- 50…300Vac single phase measured voltage
- Programmable measured quantity - active power - reactive power - apparent power - power factor - phase angle - power demand – frequency
- Analogue outputs 0…5mA, 0…10mA, 0…20mA, 4…20mA, 0…10V or 1…5Vdc
- Accuracy class 0.5 (class 0.2 frequency)
- LCD indicator for programming and display
- All parameters programmable from front cover 3 keys
- 8 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-150Vdc auxiliary supply
Call for Prices
-
- Direct connected DC current transducers
- Accuracy class 0.5 (class 0.2 frequency)
- Input current 0…500µA up to 0…1.5Adc - bidirectional from ± 250µA to ± 750mA
- Choice of output 0…20mA, 4…20mA, 0…10Vdc
- 6 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
Call for Prices
-
- Direct connected DC current transducers
- Accuracy class 0.5 (class 0.2 frequency)
- Input voltage 0…10V up to 0…600Vdc - bidirectional from ± 5mA to ± 300V
- Choice of output 0…20mA, 4…20mA, 0…10Vdc
- 6 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
Call for Prices