Rayleigh Instruments - kWh Energy Meters

kWh Energy Meters for single phase and three phase MID and non MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus RS485 RTU and Mbus.

Items 16 to 30 of 35 total

Page:
  1. 1
  2. 2
  3. 3

Grid  List 

  • Inepro PRO380-MB-CT MID Certified Dual Tariff Single and Three Phase Network Mul...

    • Single and Three phase network active energy meter
    • MID Certified (B and D)
    • CT Operated
    • Dual Tariff
    • 70mm wide/4 Module
    • Din Rail Mounted
    • LCD Display 5+2= 99999.99
    • Measured voltage 230V 50 Hz
    • Calculation of total energy : Forward, Forward+Reverse, Forward-Reverse, Reverse-Forward, Reverse
    • Pulse (settable S0) and Mbus output
    Call for Prices

  • Inepro PRO380-Standard-CT MID Certified Single Tariff Single and Three Phase Net...

    • Single and Three phase network active energy meter
    • MID Certified (B and D)
    • CT Operated
    • Single Tariff
    • 70mm wide/4 Module
    • Din Rail Mounted
    • LCD Display 5+2= 99999.99
    • Measured voltage 230V 50 Hz
    • Calculation of total energy : Forward, Forward+Reverse, Forward-Reverse, Reverse-Forward, Reverse
    • Pulse output (settable S0)
    Call for Prices

  • IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...

    • Kilowatt hour meter / active energy meter
    • 72 x 72mm flush panel mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Power demand
    • Power max demand (resettable)
    • Partial active and reactive energy (resettable)
    • Phase Current
    • Phase to phase and phase to neutral voltage
    • Frequency
    • Phase active power
    • Phase reactive power
    • 3 phase active/reactive and apparent power
    • Power factor
    • –/1A or –/5A current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulsed output
    • Programmable CT ratios
    Call for Prices

  • IME Conto D2 Class 1 Single Phase Network kWh Energy Meter (Not MID Certificated...

    • Kilowatt hour / active energy meter
    • 2 module wide
    • DIN rail mounted
    • Single phase network
    • Input current 10(63)A
    • Input voltage 230V
    • Active energy class B (EN50470)
    • Reactive energy class 2 (EN60253-23)
    • Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
    • LCD Display 5+1= 999999.9
    • Self supplied auxiliary
    • Pulse or RS485 Modbus RTU (depending on model)
    Call for Prices

  • IME Conto D4-Pd Class 1 Three Phase Network 63 Direct Connected kWh Energy Meter...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • Direct connection up to 63A
    • 3 phase 3 or 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • Partial active energy (resettable)
    • Partial reactive energy (resettable)
    • Phase current
    • Phase – neutral voltage
    • Phase – phase voltage
    • Active power (KW)
    • Reactive power (KVar)
    • Apparent power (KVA)
    • Phase active power (KW)
    • Phase reactive power (KVar)
    • Active power demand
    • Active power max demand
    • Frequency
    • Power factor
    • Hours run meter (resettable)
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulse or RS485 output
    Call for Prices

  • IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Pulse and RS485 output
    Call for Prices

  • Conto D4-Pt M-Bus

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Mbus output
    Call for Prices

  • IME IF4C001 Conto Imp Pulse Acquisition 4 Module To RS485 communication

    • Pulse imput coming from energy, gas, water, heat meters, etc
    • 12 pulse inputs SPST - NO contacts (energy, gas, water and heat meters)
    • 12 non resettable independent counting registers (max 9 digits each)
    • 3 different configuration
    • RS485 communication MODBUS/JBUS
    • Up to 255 units may be connected to a bus system
    • Data held in memory in event of power failure
    Call for Prices