Rayleigh Instruments - kWh Energy Meters
kWh Energy Meters for single phase and three phase MID and non MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus RS485 RTU and Mbus.
-
IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...
- Kilowatt hour meter / active energy meter
- 72 x 72mm flush panel mounting
- Single phase & 3 phase (3 or 4 wire) network unbalanced load
- Active energy class 1 (EN62053-21)
- Reactive energy class 2 (EN62053-23)
- Power demand
- Power max demand (resettable)
- Partial active and reactive energy (resettable)
- Phase Current
- Phase to phase and phase to neutral voltage
- Frequency
- Phase active power
- Phase reactive power
- 3 phase active/reactive and apparent power
- Power factor
- –/1A or –/5A current transformer operated
- 190…440V 50/60Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Pulsed output
- Programmable CT ratios
-
IME Conto D2 Class 1 Single Phase Network kWh Energy Meter (Not MID Certificated...
- Kilowatt hour / active energy meter
- 2 module wide
- DIN rail mounted
- Single phase network
- Input current 10(63)A
- Input voltage 230V
- Active energy class B (EN50470)
- Reactive energy class 2 (EN60253-23)
- Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
- LCD Display 5+1= 999999.9
- Self supplied auxiliary
- Pulse or RS485 Modbus RTU (depending on model)
-
IME Conto D4-Pd Class 1 Three Phase Network 63 Direct Connected kWh Energy Meter...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- Direct connection up to 63A
- 3 phase 3 or 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- Partial active energy (resettable)
- Partial reactive energy (resettable)
- Phase current
- Phase – neutral voltage
- Phase – phase voltage
- Active power (KW)
- Reactive power (KVar)
- Apparent power (KVA)
- Phase active power (KW)
- Phase reactive power (KVar)
- Active power demand
- Active power max demand
- Frequency
- Power factor
- Hours run meter (resettable)
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Pulse or RS485 output
-
IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- -/5A current transformer operated
- 3 phase 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Programmable CT ratio
- Auxiliary supply 230V 50/60Hz
- Pulse and RS485 output
-
IME IF4C001 Conto Imp Pulse Acquisition 4 Module To RS485 communication
- Pulse imput coming from energy, gas, water, heat meters, etc
- 12 pulse inputs SPST - NO contacts (energy, gas, water and heat meters)
- 12 non resettable independent counting registers (max 9 digits each)
- 3 different configuration
- RS485 communication MODBUS/JBUS
- Up to 255 units may be connected to a bus system
- Data held in memory in event of power failure