Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
Rayleigh Instruments RI-CTS024 Single Phase Clip-on Mini Split Core Current Tran...
- 100A to 300A Primary
- 5A or 1A Secondary
- 50mm width
- 24mm cable aperture
- Integral 1 metre cable
- Snap together housing
- Compact design
- Primary current flow indication
-
easywire Three Phase Current Transformer - RI-CT249-EW
- Ranges: 60 to 160A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 20 x 16mm
- 29mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT248 Three Phase Current Transformer
- Ranges: 250A to 630A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 31 x 31mm
- 45mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT248-EW
- Ranges: 250 to 630A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 31 x 31mm
- 45mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT242 Three Phase Current Transformer
- Ranges 60A to 250A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 21 x 25mm
- 35mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT242-EW
- Ranges: 60 to 250A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 25 x 21mm
- 35mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT240 Three Phase Current Transformer
- Ranges: 60A to 200A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 30 x 15.5mm
- 25mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT240-EW
- Ranges: 60 to 200A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 15 x 30mm
- 25mm hole centres
- Accuracy Class 1
-
RI-CT140H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 200A to 4000A
- 5A or 1A Secondary output
- Busbar aperture: 38 x 105mm
- Sealable terminal cover
-
RI-CT140 Single Phase Current Transformer
- Ranges: 200A to 4000A
- 5A or 1A Secondary output
- Busbar aperture: 38 x 105mm
- Sealable terminal cover
-
RI-CT130H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 150A to 2500A
- 5A or 1A Secondary output
- Busbar aperture : 34 x 84mm
- Sealable terminal cover
-
RI-CT130 Single Phase Current Transformer
- Ranges: 150A to 2500A
- 5A or 1A Secondary output
- Busbar aperture : 34 x 84mm
- Sealable terminal cover
-
RI-CT120H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 150A to 2000A
- 5A or 1A Secondary output
- Busbar apature : 32 x 65mm
- Sealable terminal cover
-
RI-CT120 Single Phase Current Transformer
- Ranges: 150A to 2000A
- 5A or 1A Secondary output
- Busbar apature : 32 x 65mm
- Sealable terminal cover
-
RI-CT080 Single Phase Current Transformer
- Ranges: 150A to 1250A
- 5A or 1A Secondary output
- Cable/Busbar aperture : 50 x 10mm, 40 x 30mm or Ø40mm