The use of MID-certified electricity meters has been made mandatory on "private"* electrical networks if there is active energy billing based on consumption readings by index differences.

Typical examples of use include: camping sites, holiday rentals, student accommodation, office buildings, shopping centres, marinas, exhibition halls, recharging systems for electric vehicles.

The EN50470-1/-3 standard defines three specific accuracy classes: A, B and C. These are comparable to the IEC62053-21/-22 active energy metering standard: Class A is equivalent to 2% accuracy, Class B to 1 % and Class C to 0.5 %.

Items 1 to 15 of 26 total

Page:
  1. 1
  2. 2

Grid  List 

  • Inepro PRO380-MOD 100A MID Certified Dual Tariff Single and Three Phase Network ...

    • Single and Three phase network active energy meter
    • MID Certified (B and D)
    • 100A Direct connected
    • Dual Tariff
    • 70mm wide/4 Module
    • Din Rail Mounted
    • LCD Display 5+2= 99999.99
    • Measured voltage 230V 50 Hz
    • Calculation of total energy : Forward, Forward+Reverse, Forward-Reverse, Reverse-Forward, Reverse
    • Pulse (settable S0) and Modbus RS485 RTU output
    Call for Prices

  • IME Conto D2 MID Certified Single Phase Network Multifunction Active Energy Mete...

    • Kilowatt hour / active energy meter
    • MID Certified (B and D)
    • 2 module wide DIN rail mounted
    • Single phase network
    • Input current 10(63)A
    • Input voltage 230V
    • LCD Display 5+1= 999999.9
    • Self supplied auxiliary
    • Pulse or RS485 Modbus RTU output (depending on model)
    Call for Prices

  • IME Conto D4-Pd MID Approved Three Phase Network Multi Function Meter Direct Con...

    • Kilowatt hour / active energy meter
    • MID Certified (B and D)
    • 4 module DIN rail mounting
    • Direct connection up to 63A
    • 3 phase 4 wire network unbalanced load
    • Active energy class B (EN50470)
    • Reactive energy class 2 (EN60253-23)
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulse and RS485 output
    Call for Prices

  • IME Conto D4-Pt CE4DMID01 MID Certified Four Module Three Phase Network MultiFu...

    • Input voltage 100…400V (phase-phase
    • MID Certified (B and D)
    • 4 module DIN rail mounting
    • 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class B (EN50470)
    • Reactive energy class 2 (EN60253-23)
    • Power demand, Power Max. demand, Phase and neutral current, Phase to phase and phase to neutral voltage, Frequency, Phase active power, Phase reactive power, 3 phase active/reactive and apparent power, Power factor
    • Hours run
    • -/5A current transformer operated
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio (1...9.999)
    • Auxiliary supply 230V 50/60Hz
    • Pulse (programmable) and RS485 Modbus RTU output
    Call for Prices

  • Elster A1140 MID Certified Three Phase Class 2 Programmable Polyphase Meter

    • Accuracy kWh Class 1 or 2 (EN 62053 -21) Wh Class A or B (EC Directive 2004/22/EC [MID]) kvarh Class 2 or 3
    • Comprehensive tariff structure
    • Instrumentation
    • Modular design to allow future upgrades
    • Large digit (9.8 mm register digits) Liquid Crystal Display
    • IEC 62056-21 (formerly IEC 61107) optical communications port
    • Internal clock and calendar with battery back-up
    • 15 years product life
    • Comprehensive security data
    • Display of external meter information
    • Compact design
    • DIN (BS) double insulated, glass filled polycarbonate case
    • IP53 in accordance with IEC 60529 : 1989
    Call for Prices

  • Elster A1700 MID Certified Class 0.5 Accuracy Three Phase Network Programmable P...

    • Direct connected, CT & CT/VT operated
    • Comprehensive tariff structure
    • 2 line, multilingual dot matrix display
    • Instantaneous instrumentation values
    • 2 module slots for extended functionality
    • 900 or 450 days load profile data
    • Accuracy Class 0.2s, 0.5s (CT only), 1 or 2
    • High security design
    Call for Prices

  • Elster A1700 MID Certified Class 1 Accuracy Three Phase Network Programmable Pol...

    • Direct connected, CT & CT/VT operated
    • Comprehensive tariff structure
    • 2 line, multilingual dot matrix display
    • Instantaneous instrumentation values
    • 2 module slots for extended functionality
    • 900 or 450 days load profile data
    • Accuracy Class 0.2s, 0.5s (CT only), 1 or 2
    • High security design
    Call for Prices