Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
RI-CT160 Single Phase Current Transformer
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
RI-CT160H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
easywire Three Phase Current Transformer - RI-CT230-EW
- 32A or 63A Primary inputs
- Sealable RJ45 connection
- Fits standard circuit breaker frames
- 330mV output
- Foot or DIN rail mounting
- 61mm width (17.5mm bar centres)
- Ø 8mm apertures
-
easywire Three Phase Current Transformer - RI-CT240-EW
- Ranges: 60 to 200A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 15 x 30mm
- 25mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT240 Three Phase Current Transformer
- Ranges: 60A to 200A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 30 x 15.5mm
- 25mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT242-EW
- Ranges: 60 to 250A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 25 x 21mm
- 35mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT242 Three Phase Current Transformer
- Ranges 60A to 250A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 21 x 25mm
- 35mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT248-EW
- Ranges: 250 to 630A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 31 x 31mm
- 45mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT248 Three Phase Current Transformer
- Ranges: 250A to 630A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 31 x 31mm
- 45mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT249-EW
- Ranges: 60 to 160A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 20 x 16mm
- 29mm hole centres
- Accuracy Class 1
-
easywire Three Phase Current Transformer - RI-CT250-EW
- Ranges: 800 to 1600A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 50 x 54mm
- 70mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT250 Three Phase Current Transformer
- Ranges: 630A to 1600A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 54 x 50mm
- 70mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
Rayleigh Instruments RI-CTS024 Single Phase Clip-on Mini Split Core Current Tran...
- 100A to 300A Primary
- 5A or 1A Secondary
- 50mm width
- 24mm cable aperture
- Integral 1 metre cable
- Snap together housing
- Compact design
- Primary current flow indication
-
Rayleigh Instruments RI-CTS036 Single Phase Clip On Mini Split Core Current Tran...
- 250A to 600A Primary
- 5A or 1A Secondary
- 57.5mm width
- 36mm cable aperture
- Integral 1 metre cable
- Snap together housing
- Compact design
- Primary current flow indication
-
RI-CBCT Series Toroid Circular Core Balanced Current Transformers
- Compact design
- 5 aperture sizes from 35 to 310mm
- Single and Three Phase compatible
- Integral fixing feet
- For residual leakage current detection
- High sensitivity and accuracy