NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9am - 5:30pm GMT/BST Monday to Friday

IME - Metering

Items 1 to 15 of 33 total

Page:
  1. 1
  2. 2
  3. 3

Grid  List 

  • IME Conto D2 MID Certified Single Phase Network Multifunction Active Energy Mete...

    • Kilowatt hour / active energy meter
    • MID Certified (B and D)
    • 2 module wide DIN rail mounted
    • Single phase network
    • Input current 10(63)A
    • Input voltage 230V
    • LCD Display 5+1= 999999.9
    • Self supplied auxiliary
    • Pulse or RS485 Modbus RTU output (depending on model)
    Call for Prices

  • IME IF96007A Nemo 96HD/HD+/HDLe PROFIBUS communication module

    • Profibus communications module for use with Nemo 96HD/HD+/HDLe models multifunction power monitors
    • Profibus EN50170
    • 3Mb/s max baud rate
    ...
    Call for Prices

  • IME IF96010 - I/O & alarm pulse counting module

    • I/O & alarm pulse counting module for use with Nemo 96HD and Nemo 96HD+ multifunction power monitors
    • Digital I/O and alarm pulse counting module
    • 2 x potential free SPST-NO contact pulse inputs
    • 2 x 8 digit counting registers for display and transmission (resettable) - typical application, gas or water meter contact input
    • Display state of input contact, open or closed
    • 2 alarm output contacts for alarm or process control
    • Min and max
    • Normally energised or de-energised
    • Hysteresis 0…20%
    • Operating delay 0…99s
    • Reset delay 0…99s
    • Contact rating 5A 250Vac Cosø 1, 3A 250Vac Cos ø 0.4, 5A 30Vdc
    Call for Prices

  • IME IF96011 - I/O & alarm pulse counting module

    • I/O & alarm pulse counting module for use with Nemo 96HD and Nemo 96HD+ multifunction power monitors
    • Digital I/O and alarm pulse counting module
    • 2 x potential free SPST-NO contact pulse inputs
    • 2 x 8 digit counting registers for display and transmission (resettable) - typical application, gas or water meter contact input
    • Display state of voltage level
    • 2 alarm output contacts for alarm or process control
    • Min and max
    • Normally energised or de-energised
    • Hysteresis 0…20%
    • Operating delay 0…99s
    • Reset delay 0…99s
    • Contact rating 5A 250Vac Cosø 1, 3A 250Vac Cos ø 0.4, 5A 30Vdc
    Call for Prices

  • IME IF2E003 - 2 module RS485 Booster Interface

    • The IF2E003 RS485 Boaster
    • Boost Signal when more than 1200m required
    • Boost Signal after every 31devices allowing up to 255 devices
    • Screw Terminals
    • Auxiliary 80-270Vac/100-300Vdc
    • Din rail mounted
    Call for Prices

  • IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
    Call for Prices

  • IME Nemo 96 HDLe (Rogowski Kit) Panel Mounted Three Phase Network Multifunction ...

    • Network monitor + 3 Rogowski current sensors
    • Three-phase network 80...500V (phase-phase)
    • Pulse output and RS485 communication
    ...
    Call for Prices

Items 1 to 15 of 33 total

Page:
  1. 1
  2. 2
  3. 3

Grid  List