Signal Conditioners

The DATEXEL range of signal conditioners includes Transmitters, Temperature converters (Both analogue and digital), galvanic isolators, signal splitters, distributed I/O modules, A/D interface modules for PLC, Trip amplifiers, Power suppliers, current loop isolators, digital meters and indicators.

Items 1 to 15 of 34 total

Page:
  1. 1
  2. 2
  3. 3

Grid  List 

  • Datexel DAT 3580-MBTCP Ethernet Gateway Modbus TCP Modbus RTU

    • D2 Din rail mounting
    • Bidirectional USB – RS485/422 converter
    • 22.5mm DIN rail mounting enclosure
    • Supply 10…30Vdc, 9…18Vac or 18…30Vac
    Call for Prices

  • Datexel DAT 5024/R2 Din Rail Configurable Trip Amplifier

    • Available analog inputs: RTD, TC, Voltage, Resistance and Current
    • Two independent threshold programmable as both high alarm or one high and one low alarm
    • Galvanic isolated among the three ways
    • Trip level and hysteresis adjustable by potentiometer
    • Delay time adjustable by potentiometer up to 25 sec.
    • Two relays SPDT 250Vac, 2A
    • High accuracy
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035
    Call for Prices

  • Datexel DAT 5024/T1 Din Rail Configurable Trip Amplifier

    • Available analog inputs: RTD, TC, Voltage, Resistance and Current
    • Two programmable independent thresholds
    • Galvanic isolated (three ways)
    • Adjustable Trip level and Hysteresis
    • Adjustable Delay time up to 25 sec.
    • Two relays SPDT 250Vac, 2A
    • High accuracy
    • EMC compliant – CE mark
    • DIN rail mounting (EN-50022 and EN50035)
    Call for Prices

  • Datexel DAT 5024/T2 Din Rail Configurable Trip Amplifier

    • Available analog inputs: RTD, TC, Voltage, Resistance and Current
    • Two programmable independent thresholds
    • Galvanic isolated (three ways)
    • Adjustable Trip level and Hysteresis
    • Adjustable Time Delay up to 25 sec.
    • Two relays SPDT 250Vac, 2A
    • High accuracy
    • EMC compliant – CE mark
    • DIN rail mounting (EN-50022 and EN50035)
    Call for Prices

  • Datexel DAT 5024/V1 Din Rail Configurable Trip Amplifier

    • Available analog inputs: RTD, TC, Voltage, Resistance and Current
    • Two independent threshold programmable - 2 x high alarm or 1 high and 1 low alarm
    • Galvanic isolated (three ways)
    • Trip level and hysteresis adjustable by potentiometer
    • Delay time adjustable by potentiometer up to 25 sec.
    • Two relays SPDT 250Vac, 2A
    • High accuracy
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting (EN-50022 and EN50035)
    Call for Prices

  • Datexel DAT 5024/V2 Din Rail Configurable Trip Amplifier

    • Available analog inputs: RTD, TC, Voltage, Resistance and Current
    • Two independent threshold programmable as both high alarm or one high and one low alarm
    • Galvanic isolated (three ways)
    • Trip level and hysteresis adjustable by potentiometer
    • Delay time adjustable by potentiometer up to 25 sec.
    • Two relays SPDT 250Vac, 2A
    • High accuracy
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting (EN-50022 and EN50035)
    Call for Prices

  • Datexel DAT 5024E/1 Economic, isolated Trip Amplifier configurable by Dip-swit...

    • Input for Voltage and Current
    • Two independent thresholds
    • Type of alarm programmable by dip-switch as high or low
    • Galvanic isolated (three ways)
    • Trip level and hysteresis adjustable by potentiometers
    • Delay time adjustable by potentiometer from 1 up to 6 sec.
    • Two relays SPDT (Form C)
    • Good accuracy and linearity
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting (EN-50022 and EN-50035)
    Call for Prices

  • Datexel DAT 5024E/2 Economic, isolated Trip Amplifier configurable by Dip-swit...

    • Input for Voltage and Current
    • Two independent thresholds
    • Type of alarm programmable by dip-switch as high or low
    • Galvanic isolated (three ways)
    • Trip level and hysteresis adjustable by potentiometers
    • Delay time adjustable by potentiometer from 1 up to 6 sec.
    • Two relays SPDT (Form C)
    • Good accuracy and linearity
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting (EN-50022 and EN-50035)
    Call for Prices

  • Datexel DAT 2166 Double Channel Programmable Converter for Pt100

    • Pt100 input
    • Input range programmable either with °C or °F unit measure
    • Zero e Span values programmable by DIP-switches
    • Voltage or current linearised outputs
    • Good accuracy and performance stability
    • EMC compliant – CE mark
    • DIN rail mounting in according to EN-50022 and EN-50035 standards
    Call for Prices

  • Datexel DAT4035 IS ATEX Din rail universal PC configurable Transmitter. Input : ...

    • PROTECTION MODE: II 1 G Ex ia IIC T6,T5,T4 Ga certified in according to the Directive ATEX 94/9/EC
    • Applicable in zones with explosion risk (ZONE 0)
    • Configurable input for RTD, mV, Tc, Resistance and Potentiometer
    • 4 ÷ 20 mA configurable output on current loop
    • Galvanic isolation at 2000 Vac
    • Configurable by Personal Computer, on-field reconfigurable
    • High accuracy
    • EMC compliant – CE mark
    • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035
    Call for Prices

  • Datexel DAT 3011 Remote I/O Module Universal I/O on RS-485 Network

    • Field-Bus remote data acquisition
    • Modbus Slave device on RS-485
    • Modbus RTU Protocol
    • 1 Universal Analogue Input + 1 Analogue Input V/mA
    • 2 Analogue Outputs 0-20mA
    • 3 Digital Inputs
    • 1 SSR Digital Output + 2 SPST Relay Outputs
    • Watch-Dog Alarm
    • Remotely Configurable
    • 1500 Vac galvanic isolation on all the ways
    • High Accuracy
    • UL / CE mark
    • DIN rail mounting in compliance with EN-50022
    Call for Prices