  • Rayleigh Instruments RI-F400 easywire Multifunction Meter

    • DIN 96 panel mounted
    • 330mV Input from easywire® CTs
    • Single phase or three phase network compatible
    • Programmable voltage and CT ratio
    • True RMS measurement
    • Pulse output and Modbus communication
    Call for Prices

  • IME Conto 72-Sh Single and Three Phase Network Panel Mounted MultiFunction Netwo...

    • Kilowatt hour meter / active energy meter
    • 72 x 72mm flush panel mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Power demand
    • Power max demand (resettable)
    • Partial active and reactive energy (resettable)
    • Phase Current
    • Phase to phase and phase to neutral voltage
    • Frequency
    • Phase active power
    • Phase reactive power
    • 3 phase active/reactive and apparent power
    • Power factor
    • –/1A or –/5A current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulsed output
    • Programmable CT ratios
    Call for Prices

  • IME Conto D4-Sh Class 1 Single Phase & Three Phase Network Multi-Function Me...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • –/1A ,-/5A or 0.333V current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Programmable CT ratios
    • Pulsed or RS485 output
    Call for Prices

  • IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc
    Call for Prices

  • IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multi-Function Me...

    • 4 module DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Isolated input
    • Phase sequence diagnostics
    • Pulsed output, Modbus RS485 communication or M-Bus communication
    • –/1A, –/5A current transformer operated
    • 50…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    Call for Prices

  • IME Nemo 72-L Panel Mounted Multi Function Meter Single and Three Phase Network ...

    • 72 x 72mm panel mounting meter
    • Single-phase network 50...290V
    • Three-phase network 80...500V (phase - phase)
    • Current Transformer Input :- Current rating In: 5a or 1a
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor, Partial active energy (resettable), Hours run, Phase sequence diagnostics
    • Integrated Communication Protocols are *Pulsed output or *RS485 Modbus RTU (*depending on model ordered)
    • True RMS value measurement
    • External CT and VT programmable (External CT ratio: 1...9999) - (External VT ratio: 1...10,0)
    • Programmable voltage transformer ratio
    • Auxillary Supply - Rated value Uaux ac: 48 - 115 – 230 e 240v
    Call for Prices

  • Rayleigh Instruments RI-F421 (80-500V) Single and Three Phase Network High Accur...

    • DIN 96x96mm flush mounting meter with backlit LCD display
    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-500V 50/60 Hz (phase to phase)
    • Current Transformer Connected 1A or - 5A CT Input
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Programmable settings:
    • Input current via CT 5/5A to 50000/5A or 5/1A to 50000/1A
    • Direct voltage input 80 to 500V (phase to phase)
    • Voltage input via VT upto 1000V on VT primary
    Call for Prices

  • IME Nemo 96 HD Panel Mounted Single & Three Phase Network 0.5 Accuracy Class...

    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-500V 50/60 Hz (phase to phase)
    • Auxiliary Voltage 80-265Vac/110-300Vdc
    • -/1A or -/5A CT Input selectable
    Call for Prices

14 Item(s)