  • Rayleigh Instruments RI-384-C Din Rail Mounted Energy Meter

    Rayleigh Instruments RI-D384-C Single & Three Phase Network Multifunction Energy Meter

    • Single Phase Network or 3 phase 3 or 4 wire Network unbalanced load operation
    • -/1A or -/5A current transformer operated
    • Integrated RS485 Modbus RTU Communication
    • Din Rail Mounted - 4 Module Wide

    from: £97.00 ex VAT £116.40 inc VAT

  • RI-F384 Multifunction Energy Meter Panel Mounting grey

    Rayleigh Instruments RI-F384 Single & Three Phase Network Multifunction Meter Analyser

    • Single Phase Network or 3 phase 3 or 4 wire Network unbalanced load operation
    • 5A / 1A Current Transformer Input
    • Integrated Communication Protocols are Pulsed output and RS485 Modbus RTU
    • Panel Mounted (96x96mm)

    from: £120.95 ex VAT £145.14 inc VAT

  • IME NEMO D4-LE

    IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Meter

    • 4 module wide 71.22mm
    • DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Partial active energy and reactive energy(resettable)
    • Hours run, Phase sequence diagnostics, Harmonic analysis, Crest factor, Phase angle
    • Integrated Communication Protocols are *Pulsed output, *RS485 Modbus RTU (*depending on model ordered) or BACNET
    • –/1A or –/5A (selectable) current transformer operated
    • 80…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 80-265Vac/110-300Vdc or 20…150Vdc

    from: £105.00 ex VAT £126.00 inc VAT

  • Nemo D4-L+ isolated input energy meter

    IME Nemo D4-L+ Din Rail Single Phase & Three Phase Network Multi-Function Meter

    • 4 module DIN rail mounting
    • Single & three phase (3 or 4 wire) network unbalanced load
    • Isolated input
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active, reactive and apparent power, Phase active and reactive power, Average power, Peak power (resettable), Power factor, Partial active energy (resettable), Hours run
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Phase sequence diagnostics
    • Pulsed output, Modbus RS485 communication or M-Bus communication
    • –/1A, –/5A current transformer operated
    • 50…450V direct or VT operated measured voltage
    • Programmable current transformer ratio
    • Programmable voltage transformer ratio
    • Auxiliary 48/115/230Vac, 20…150Vdc

    from: £184.60 ex VAT £221.52 inc VAT

  • Nemo 72-L multifunction power meter

    IME Nemo 72-L Panel Mounted Multi Function Meter Single and Three Phase Network with Current Transformer Connection 5A or 1A

    • 72 x 72mm panel mounting meter
    • Single-phase network 50...290V
    • Three-phase network 80...500V (phase - phase)
    • Current Transformer Input :- Current rating In: 5a or 1a
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Voltage, Current, Neutral current, Average current, Peak current (resettable), Frequency, Active and reactive apparent power, Phase active and reactive apparent power, Average power, Peak power (resettable), Power factor, Partial active energy (resettable), Hours run, Phase sequence diagnostics
    • Integrated Communication Protocols are *Pulsed output or *RS485 Modbus RTU (*depending on model ordered)
    • True RMS value measurement
    • External CT and VT programmable (External CT ratio: 1...9999) - (External VT ratio: 1...10,0)
    • Programmable voltage transformer ratio
    • Auxillary Supply - Rated value Uaux ac: 48 - 115 – 230 e 240v

    from: £135.69 ex VAT £162.83 inc VAT

  • RI-F421 Front

    Rayleigh Instruments RI-F421 (80-500V) Single and Three Phase Network High Accuracy Multifunction Meter With Pulse Output & RS485 Modbus RTU

    • DIN 96x96mm flush mounting meter with backlit LCD display
    • Single phase or 3-phase, 3 or 4-wire unbalanced load operation
    • Measured Voltage 80-500V 50/60 Hz (phase to phase)
    • Current Transformer Connected 1A or - 5A CT Input
    • Active energy class 0.5 (EN61557-12)
    • Reactive energy class 1 (EN61557-12)
    • Programmable settings:
    • Input current via CT 5/5A to 50000/5A or 5/1A to 50000/1A
    • Direct voltage input 80 to 500V (phase to phase)
    • Voltage input via VT upto 1000V on VT primary

    from: £129.00 ex VAT £154.80 inc VAT