  • Rayleigh Instruments 368 Single Phase and Three Phase Panel Mounted Kilowatt Hour Meter CT Operated Front

    Rayleigh Instruments RI-F368 Single Phase and Three Phase Panel Mounted Kilowatt Hour Meter CT Operated

    • Single phase and 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1
    • -/5A or -/1A current transformer operated
    • Panel mounting
    • Modbus RS485 or pulse output

    from: £65.81 ex VAT £65.81 inc VAT

  • Conto D2 - energy meter

    IME Conto D2 Class 1 Single Phase Network Multifunction Kilowatt Energy Meter (Not MID Certificated)

    • Kilowatt hour / active energy meter
    • 2 module wide
    • DIN rail mounted
    • Single phase network
    • Input current 10(63)A
    • Input voltage 230V
    • Active energy class B (EN50470)
    • Reactive energy class 2 (EN60253-23)
    • Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
    • LCD Display 5+1= 999999.9
    • Self supplied auxiliary
    • Pulse or RS485 Modbus RTU (depending on model)

    from: £60.33 ex VAT £72.40 inc VAT

  • Conto D4-Pd - energy meter

    IME Conto D4-Pd Class 1 Three Phase Network 63 Direct Connected Multi Function Energy Meter

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • Direct connection up to 63A
    • 3 phase 3 or 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • Partial active energy (resettable)
    • Partial reactive energy (resettable)
    • Phase current
    • Phase – neutral voltage
    • Phase – phase voltage
    • Active power (KW)
    • Reactive power (KVar)
    • Apparent power (KVA)
    • Phase active power (KW)
    • Phase reactive power (KVar)
    • Active power demand
    • Active power max demand
    • Frequency
    • Power factor
    • Hours run meter (resettable)
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulse or RS485 output

    from: £135.69 ex VAT £162.83 inc VAT

  • Conto D4-Pt - energy meter

    IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network Multifunction Meter - Connection by CT/1A and /5A

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Pulse and RS485 output

    from: £113.07 ex VAT £135.68 inc VAT

  • Conto D4-Pt DIN Rail Meter

    Conto D4-Pt M-Bus

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Mbus output

    from: £0.00 ex VAT £0.00 inc VAT